Title: | Sensitivity of the Oxford Foot Model to marker misplacement: A systematic single-case investigation | Authors: | Walsh, H. P. J. Carty, Christopher Gillett, J. G. |
Issue Date: | 2015 | Source: | 42, (3), 2015, p. 398-401 | Pages: | 398-401 | Journal: | Gait and Posture | Abstract: | The purpose of this paper was to systematically assess the effect of Oxford Foot Model (OFM) marker misplacement on hindfoot relative to tibia, and forefoot relative to hindfoot kinematic calculations during the stance phase of gait. Marker trajectories were recorded with an 8-camera motion analysis system (Vicon Motion Systems Ltd., UK) and ground reaction forces were recorded from three force platforms (AMTI, USA). A custom built marker cluster consisting of 4 markers in a square arrangement (diagonal distance 2. cm) was used to assess the effect of marker misplacement in the superior, inferior, anterior and posterior direction for the sustentaculum tali (STL), the proximal 1st metatarsal (P1M), distal 5th metatarsal (D5M), proximal 5th metatarsal (P5M) and lateral calcaneus (LCA) markers. In addition manual movement of the heel complex 1. cm superiorly, inferiorly, medially and laterally, and also an alignment error of 10° inversion and 10° eversion was assessed. Clinically meaningful effects of marker misplacement were determined using a threshold indicating the minimal clinically important difference. Misplacement of the heel-wand complex had the most pronounced effect on mean kinematic profiles during the stance phase across all degrees-of-freedom with respect to hindfoot-tibia and forefoot-hindfoot angles. Vertical marker misplacement of the D5M and P5M markers affected the sagittal plane, and to a lesser extent frontal plane, forefoot-hindfoot kinematics. In conclusion, the OFM is highly sensitive to misplacement of the heel-wand complex in all directions and the P5M marker in the vertical direction.L6051384592015-07-14 | DOI: | 10.1016/j.gaitpost.2015.06.189 | Resources: | https://www.embase.com/search/results?subaction=viewrecord&id=L605138459&from=exporthttp://dx.doi.org/10.1016/j.gaitpost.2015.06.189 | | Keywords: | motion analysis system;Oxford Foot Model;priority journal;sensitivity analysis;tibia;kinematics;forefoot;human;gait;model;ground reaction force;articlecalcaneus;metatarsal bone;hindlimb | Type: | Article |
Appears in Sites: | Children's Health Queensland Publications |
Show full item record
Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.