Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/6936
Title: Comparison of Refractive Prediction Errors of Toric Intraocular Lens Formulae
Authors: Bai, Michelle 
Ong, Keith
Issue Date: 2025
Source: Bai M, Ong K. Comparison of Refractive Prediction Errors of Toric Intraocular Lens Formulae. Cureus. 2025 Feb 26;17(2):e79679. doi: 10.7759/cureus.79679. PMID: 40161103; PMCID: PMC11954418.
Journal Title: Cureus
Journal: Cureus
Abstract: Introduction Toric intraocular lenses (IOLs) are effective in correcting astigmatism; however, with multiple IOL toric formulae available, identifying the most accurate formula is important. The IOLMaster 700 (Carl Zeiss Meditec AG, Jena, Germany) provides two in-built toric IOL formulae, the Barrett TK Toric (BTT) and Haigis Toric (HT), which sometimes differ in astigmatism predictions for a particular IOL power. This study investigates the accuracy of these formulae in predicting postoperative refraction. Methods This retrospective study included 52 eyes from 52 patients undergoing uncomplicated cataract surgery with AcrySof IQ Toric IOL implantation (Alcon Laboratories Inc., Fort Worth, Texas, United States). Biometric data, including axial length, anterior chamber depth, lens thickness, and total keratometry, were measured using the IOLMaster 700. Predicted residual spherical equivalence (SE) and astigmatism were calculated using BTT and HT formulae. Postoperative refractive outcomes were assessed at least four weeks post-surgery. Differences in prediction errors in SE and astigmatism were assessed. Results The median absolute error in SE prediction was comparable between BTT and HT formulae (0.195 D vs. 0.185 D; p=1.000), with no significant difference in the proportion of eyes achieving absolute prediction errors ≤0.25 D, ≤0.50 D, ≤0.75 D, or ≤1.00 D. For astigmatism, the HT formula demonstrated lower mean absolute errors (MAE: 0.41±0.33 D) and centroid errors (0.18 D @ 70°) compared to BTT (MAE: 0.47±0.36 D; centroid error: 0.32 D @ 76°; p<0.001). Conclusion Both BTT and HT formulae exhibit similarly high accuracy in predicting postoperative SE. HT performed statistically better for astigmatism prediction; however, the difference was negligible and not clinically significant.
Description: Cairns & Hinterland Hospital and Health Service (CHHHS) affiliated author: Michelle Bai
DOI: 10.7759/cureus.79679
Keywords: astigmatism correction;iol power calculation formula;refractive cataract surgery;refractive prediction error;spherical equivalence;toric intraocular lens
Type: Article
Appears in Sites:Cairns & Hinterland HHS Publications
Queensland Health Publications

Show full item record

Page view(s)

38
checked on Jun 12, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.