Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/6054
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarsh, N.-
dc.contributor.authorLarsen, E. N.-
dc.contributor.authorUllman, A. J.-
dc.contributor.authorMihala, G.-
dc.contributor.authorCooke, M.-
dc.contributor.authorChopra, V.-
dc.contributor.authorRay-Barruel, G.-
dc.contributor.authorRickard, C. M.-
dc.date.accessioned2024-06-20T00:29:59Z-
dc.date.available2024-06-20T00:29:59Z-
dc.date.issued2023-
dc.identifier.citationInternational journal of nursing studies, 2023 (151) p.104673en
dc.identifier.urihttps://dora.health.qld.gov.au/qldresearchjspui/handle/1/6054-
dc.description.abstractBACKGROUND: Peripheral intravenous catheters are the most frequently used invasive device in nursing practice, yet are commonly associated with complications. We performed a systematic review to determine the prevalence of peripheral intravenous catheter infection and all-cause failure. METHODS: The Cochrane Library, PubMed, CINAHL, and EMBASE were searched for observational studies and randomised controlled trials that reported peripheral intravenous catheter related infections or failure. The review was limited to English language and articles published from the year 2000. Pooled estimates were calculated with random-effects models. Meta-analysis of observation studies in epidemiology guidelines and the Cochrane process for randomised controlled trials were used to guide the review. Prospero registration number: CRD42022349956. FINDINGS: Our search retrieved 34,725 studies. Of these, 41 observational studies and 28 randomised controlled trials (478,586 peripheral intravenous catheters) met inclusion criteria. The pooled proportion of catheter-associated bloodstream infections was 0.028 % (95 % confidence interval (CI): 0.009-0.081; 38 studies), or 4.40 catheter-associated bloodstream infections per 100,000 catheter-days (20 studies, 95 % CI: 3.47-5.58). Local infection was reported in 0.150 % of peripheral intravenous catheters (95 % CI: 0.047-0.479, 30 studies) with an incidence rate of 65.1 per 100,000 catheter-days (16 studies; 95 % CI: 49.2-86.2). All cause peripheral intravenous catheter failure before treatment completion occurred in 36.4 % of catheters (95 % CI: 31.7-41.3, 53 studies) with an overall incidence rate of 4.42 per 100 catheter days (78,891 catheter days; 19 studies; 95 % CI: 4.27-4.57). INTERPRETATION: Peripheral intravenous catheter failure is a significant worldwide problem, affecting one in three catheters. Per peripheral intravenous catheter, infection occurrence was low, however, with over two billion catheters used globally each year, the absolute number of infections and associated burden remains high. Substantial and systemwide efforts are needed to address peripheral intravenous catheter infection and failure and the sequelae of treatment disruption, increased health costs and poor patient outcomes.-
dc.language.isoEnglish-
dc.titlePeripheral intravenous catheter infection and failure: A systematic review and meta-analysis-
dc.typeArticle in Press-
dc.identifier.doi10.1016/j.ijnurstu.2023.104673-
dc.relation.urlhttps://www.embase.com/search/results?subaction=viewrecord&id=L643103184&from=export-
dc.relation.urlhttp://dx.doi.org/10.1016/j.ijnurstu.2023.104673-
dc.identifier.journaltitleInternational journal of nursing studies-
dc.identifier.risid4472-
dc.description.pages104673-
dc.description.volume151-
item.openairetypeArticle in Press-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1English-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Sites:Children's Health Queensland Publications
Show simple item record

Page view(s)

28
checked on Nov 22, 2024

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.