Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/5981
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKleidon, Tricia M.-
dc.contributor.authorGibson, Victoria-
dc.contributor.authorCattanach, Paula-
dc.contributor.authorSchults, Jessica-
dc.contributor.authorRoyle, Ruth H.-
dc.contributor.authorWare, Robert S.-
dc.contributor.authorMarsh, Nicole-
dc.contributor.authorPitt, Colleen-
dc.contributor.authorDean, Anna-
dc.contributor.authorByrnes, Joshua-
dc.contributor.authorRickard, Claire M.-
dc.contributor.authorUllman, Amanda J.-
dc.date.accessioned2024-06-20T00:29:18Z-
dc.date.available2024-06-20T00:29:18Z-
dc.date.issued2023-
dc.identifier.citationJAMA pediatrics, 2023 (177) 11 p.1132-1140en
dc.identifier.urihttps://dora.health.qld.gov.au/qldresearchjspui/handle/1/5981-
dc.description.abstractImportance: Peripheral intravenous catheters (PIVCs) frequently fail during treatment causing therapy interruption, pain, recatheterization, and additional health care costs. Midline catheters (MCs) may improve functional dwell time and reduce failure compared with traditional PIVCs.; Objective: To compare device failure of MCs with PIVCs.; Design, Setting, and Participants: This was a pragmatic, randomized clinical superiority trial with an embedded internal pilot study conducted from July 2020 to May 2022. The study took place in a quaternary pediatric hospital in Brisbane, Queensland, Australia. Inclusion criteria were patients aged 1 to 18 years requiring peripherally compatible intravenous therapy for 4 days or longer.; Interventions: Patients were randomly assigned 1:1 to receive a PIVC or MC, stratified by age (≤5 years, >5 years). One catheter was studied per patient.; Main Outcomes and Measures: The primary outcome was all-cause device failure, defined as premature cessation of device function. Secondary outcomes included number of insertion attempts, insertion failure, pain (on insertion), procedural time, patient/parent satisfaction (with insertion), device dwell time, device complications during dwell time, additional vascular access devices required to complete treatment, clinician satisfaction (at removal), and health care costs.; Results: Of the 128 patients randomly assigned to study groups, 127 patients (median [IQR] age, 7 [2-13] years; 71 male [56%]) had a device inserted, with 65 (51.2%) in the PIVC group and 62 (48.8%) in the MC group. All patients were included in the intention-to-treat analysis. Device failure was lower in patients in the MC group (10 [16.1%]) compared with those in the PIVC group (30 [46.2%]; odds ratio [OR], 0.22; 95% CI, 0.10-0.52; P <.001). MCs were associated with fewer insertion attempts (mean difference [MD], -0.3; 95% CI, -0.5 to 0; P = .04), increased dwell time (MD, 66.9 hours; 95% CI, 36.2-97.5 hours; P <.001), and fewer patients required additional vascular access devices to complete treatment in the MC group (4 [6.5%]) and PIVC group (19 [29.2%]; OR, 0.17; 95% CI, 0.05-0.52; P = .002). Compared with PIVCs, use of MCs was associated with greater patient (9.0 vs 7.1 of 10; P = .002) and parent (9.1 vs 8.2 of 10; P = .02) satisfaction and lower health care costs (AUS -$151.67 [US -$101.13] per person; 95% credible interval, AUS -$171.45 to -$131.90 [US -$114.20 to -$87.95]).; Conclusions and Relevance: Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure.; Trial Registration: Australia New Zealand Clinical Trials Registry, ACTRN12620000724976.-
dc.titleMidline Compared With Peripheral Intravenous Catheters for Therapy of 4 Days or Longer in Pediatric Patients: A Randomized Clinical Trial-
dc.identifier.doi10.1001/jamapediatrics.2023.3526-
dc.relation.urlhttps://search.ebscohost.com/login.aspx?direct=true&AuthType=ip,athens&db=mdc&AN=37695594&site=ehost-live-
dc.identifier.journaltitleJAMA pediatrics-
dc.identifier.risid4091-
dc.description.pages1132-1140-
dc.description.volume177-
dc.description.issue11-
item.grantfulltextnone-
item.fulltextNo Fulltext-
Appears in Sites:Children's Health Queensland Publications
Show simple item record

Page view(s)

48
checked on Nov 26, 2024

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.