Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/5461
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMcLean, Annaen
dc.contributor.authorBarr, Elizabethen
dc.contributor.authorTabuai, Georginaen
dc.contributor.authorMurphy, Helen Ren
dc.contributor.authorMaple-Brown, Louiseen
dc.date.accessioned2024-02-16T02:34:40Z-
dc.date.available2024-02-16T02:34:40Z-
dc.date.issued2023-
dc.identifier.citationMcLean A, Barr E, Tabuai G, Murphy HR, Maple-Brown L. Continuous Glucose Monitoring Metrics in High-Risk Pregnant Women with Type 2 Diabetes. Diabetes Technol Ther. 2023 Dec;25(12):836-844. doi: 10.1089/dia.2023.0300. Epub 2023 Oct 30. PMID: 37902969; PMCID: PMC10698759.en
dc.identifier.urihttps://dora.health.qld.gov.au/qldresearchjspui/handle/1/5461-
dc.descriptionCairns & Hinterland Hospital and Health Service (CHHHS) affiliated authors: Anna McLean, Georgina Tabuaien
dc.description.abstractObjective: To describe glucose metrics in a high-risk population of women with type 2 diabetes (T2DM) in pregnancy and to explore the associations with neonatal outcomes. Research Design and Methods: Prospective observational study of 57 women. Continuous glucose monitoring (CGM) trajectories were determined from metrics collected in early and late gestation using the first and last two (mean 16 and 35) weeks of Freestyle Libre data. Logistic regression was used to examine associations of CGM metrics with neonatal hypoglycemia (glucose <2.6 mmol/L requiring intravenous dextrose) and large for gestational age (LGA) (>90th percentile for gestational age and sex). Pregnancy-specific target glucose range was 3.5-7.8 mmol/L (63-140 mg/dL). Results: Forty-one women used CGM for 15 weeks (mean age 33 years, 73% Aboriginal or Torres Strait Islander, 32% living remotely). There was limited change in average metrics from early to late pregnancy. For the subgroup with sensor use >50% (n = 29), mean time in range (TIR) increased by 9%, time above range reduced by 12%, average glucose reduced by 1 mmol/L, and time below range increased by 3%. Neonatal hypoglycemia was associated with most CGM metrics, HbA1c and CGM targets, particularly those from late pregnancy. LGA was associated with hyperglycemic metrics from early pregnancy. Each 1% increase TIR was associated with a 4%-5% reduction in risk of neonatal complications. Conclusion: In this high-risk group of women with T2DM, CGM metrics only improved during pregnancy in those with greater sensor use and were associated with LGA in early pregnancy and neonatal hypoglycemia throughout. Culturally appropriate health care strategies are critical for successful use of CGM technology.en
dc.language.isoenen
dc.relation.ispartofDiabetes technology & therapeuticsen
dc.subjectGlucose metricsen
dc.subjectFlash glucose monitoringen
dc.subjectContinuous glucose monitoringen
dc.subjectType 2 diabetesen
dc.subjectPregnancyen
dc.subjectIndigenousen
dc.subjectAboriginal and Torres Strait Islanderen
dc.titleContinuous Glucose Monitoring Metrics in High-Risk Pregnant Women with Type 2 Diabetesen
dc.typeArticleen
dc.identifier.doi10.1089/dia.2023.0300-
dc.identifier.pmid37902969-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.openairetypeArticle-
Appears in Sites:Cairns & Hinterland HHS Publications
Files in This Item:
File Description SizeFormat 
Continuous glucose monitoring metrics in high-risk pregnant women with Type 2 Diabetes.pdf912.16 kBAdobe PDFThumbnail
View/Open
Show simple item record

Page view(s)

78
checked on Dec 23, 2024

Download(s)

74
checked on Dec 23, 2024

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.