Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/4070
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChopra, V.en
dc.contributor.authorUllman, Amandaen
dc.contributor.authorMihala, G.en
dc.contributor.authorRickard, C. M.en
dc.contributor.authorMarsh, N.en
dc.contributor.authorLarsen, E. N.en
dc.contributor.authorTakashima, M.en
dc.contributor.authorKleidon, Ten
dc.contributor.authorKeogh, S.en
dc.date.accessioned2022-11-07T23:49:00Z-
dc.date.available2022-11-07T23:49:00Z-
dc.date.issued2021-
dc.identifier.citationDec 124 , 2021, p. 104095en
dc.identifier.urihttp://dora.health.qld.gov.au/qldresearchjspui/handle/1/4070-
dc.description.abstractBACKGROUND: Peripheral intravenous catheters are an essential medical device which are prone to complications and failure. OBJECTIVES: Identify patient, provider and device risk factors associated with all-cause peripheral intravenous catheter failure as well as individual complications: phlebitis, infiltration/occlusion, and dislodgement to improve patient outcomes. DESIGN: Secondary analysis of twelve prospective studies performed between 2008 and 2020. SETTINGS: Australian metropolitan and regional hospitals including one paediatric hospital. PARTICIPANTS: Participants were from medical, surgical, haematology, and oncology units. METHODS: Multilevel mixed-effects parametric survival regression was used to identify factors associated with all-cause peripheral intravenous catheter failure, phlebitis, occlusion/infiltration, and dislodgement. We studied patient (e.g., age, gender), device (e.g., gauge), and provider (e.g., inserting clinician) variables. Stepwise regression involved clinically and p<0.20 significant variables entered into the multivariable model. Results were expressed as hazard ratios (HRs) and 95% confidence intervals (CI); p<0.01 was considered statistically significant. RESULTS: Of 11,830 peripheral intravenous catheters (8,200 participants) failure occurred in 36% (n = 4,263). Occlusion/infiltration incidence was 23% (n = 2,767), phlebitis 12% (n = 1,421), and dislodgement 7% (n = 779) of catheters. Patient factors significantly associated with failure and complications were: female gender (phlebitis; (HR 1.98, 95% CI 1.72-2.27), (infiltration/occlusion; HR 1.45, 95% CI 1.33-1.58), (failure; HR 1.36, 95% CI 1.26-1.46); and each year increase in age (phlebitis; 0.99 HR, 95% CI 0.98-0.99), (failure; 0.99 HR, 95% CI 0.99-0.99). The strongest provider risk factor was intravenous antibiotics (infiltration/occlusion; HR 1.40, 95% CI 1.27-1.53), (phlebitis; HR 1.36, 95% CI 1.18-1.56), (failure; HR 1.26, 95% CI 1.17-1.36). Catheters inserted by vascular access teams were less likely to dislodge (HR 0.53, 95% CI 0.42-0.67). Device risk factors most associated with all-cause failure were wrist/hand (HR 1.34, 95% CI 1.23-1.46), antecubital fossa peripheral intravenous catheters (HR 1.29, 95% CI 1.16-1.44) and 22/24 gauge (HR 1.27, 95% CI 1.12-1.45) catheters. CONCLUSION: Factors identified, including the protective aspect of vascular access team insertion, and high catheter failure associated with intravenous antibiotic administration, will allow targeted updates of peripheral intravenous catheter guidelines and models of care.1873-491xMarsh, Nicole <br />Larsen, Emily N <br />Takashima, Mari <br />Kleidon, Tricia <br />Keogh, Samantha <br />Ullman, Amanda J <br />Mihala, Gabor <br />Chopra, Vineet <br />Rickard, Claire M <br />Journal Article <br />England <br />Int J Nurs Stud. 2021 Dec;124:104095. doi: 10.1016/j.ijnurstu.2021.104095. Epub 2021 Sep 26. <br />en
dc.language.isoenen
dc.relation.ispartofInt J Nurs Studen
dc.titlePeripheral intravenous catheter failure: A secondary analysis of risks from 11,830 cathetersen
dc.typeArticleen
dc.identifier.doi10.1016/j.ijnurstu.2021.104095-
dc.subject.keywordsCathetersen
dc.subject.keywordsChilden
dc.subject.keywordsCatheterization, peripheralen
dc.subject.keywordsVascular access devicesen
item.languageiso639-1en-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Sites:Children's Health Queensland Publications
Queensland Health Publications
Show simple item record

Page view(s)

102
checked on May 8, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.