Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/2211
Title: Central venous Access device SeCurement and Dressing Effectiveness (CASCADE) in paediatrics: Protocol for pilot randomised controlled trials
Authors: Mihala, G.
Cooke, M.
Rickard, C. M.
Ullman, Amanda 
Kleidon, T 
Gibson, V.
Long, D. A.
Williams, T.
McBride, C. A.
Hallahan, A.
Issue Date: 2016
Source: 6, (6), 2016
Journal: BMJ Open
Abstract: Introduction: Paediatric central venous access devices (CVADs) are associated with a 25% incidence of failure. Securement and dressing are strategies used toreduce failure and complication; however, innovative technologies have not been evaluated for their effectiveness across device types. The primary aim of this research is to evaluate the feasibility of launching a full-scale randomised controlled efficacy trial across three CVAD types regarding CVAD securement and dressing, using predefined feasibility criteria. Methods and analysis: Three feasibility randomised, controlled trials are to be undertaken at the Royal Childrens Hospital and the Lady Cilento Childrens Hospital, Brisbane, Australia. CVAD securement and dressing interventions under examination compare current practice with sutureless securement devices, integrated securement dressings and tissue adhesive. In total, 328 paediatric patients requiring a peripherally inserted central catheter (n=100); non-tunnelled CVAD (n=180) and tunnelled CVAD (n=48) to be inserted will be recruited and randomly allocated to CVAD securement and dressing products. Primary outcomes will be study feasibility measured by eligibility, recruitment, retention, attrition, missing data, parent/staff satisfaction and effect size. CVAD failure and complication (catheter-associated bloodstream infection, local infection, venous thrombosis, occlusion, dislodgement and breakage) will be compared between groups. Ethics and dissemination: Ethical approval to conduct the research has been obtained. All dissemination will be undertaken using the CONSORT Statement recommendations. Additionally, the results will be sent to the relevant organisations which lead CVAD focused clinical practice guidelines development.L6106376912016-06-16
2016-06-27
DOI: 10.1136/bmjopen-2016-011197
Resources: https://www.embase.com/search/results?subaction=viewrecord&id=L610637691&from=exporthttp://dx.doi.org/10.1136/bmjopen-2016-011197 |
Keywords: suture;vein thrombosis;Biopatch 44150;GripLok 3601CVC;Histoacryl;Prolene;SorbaView SHIELD SV353;Statlock VPPCSP;Tegaderm 1616;Tegaderm 1655;ACTRN12614000280606central venous catheter;tissue adhesive;adolescent;adult;article;Australia;bloodstream infection;catheter infection;child;controlled study;device failure;feasibility study;human;major clinical study;medical device complication;occlusion;outcome assessment;patient satisfaction;pediatrics;peripherally inserted central venous catheter;pilot study;randomized controlled trial
Type: Article
Appears in Sites:Children's Health Queensland Publications

Show full item record

Page view(s)

98
checked on Mar 20, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.