dc.description.abstractAim: This review aims to present a case series on pressure injury (PI) formation secondary to limb-splinting for preservation of peripheral intravascular catheter (PIVC) access in neonatal and pediatric patients. A literature review was undertaken to analyze the existing knowledge base on this phenomenon. Background: Medical devices and attachments are considered a risk factor for PI development in neonates, infants, and children. Three cases of PI formation caused by contact with limb boards used to preserve PIVC access were identified in an Australian tertiary pediatric facility during 2016. Methods: A literature search was conducted during December 2017 using the Cumulative Index of Nursing and Allied Health, Excerpta Medica database, MEDLINE, PubMed, and the Cochrane Library. Keywords used were pressure injury(ies), pressure ulcer, pressure ulcers, decubitus ulcer, and decubitus ulcers. Articles were excluded if published before 2006, patients were adolescents or adults, and if injuries were not caused by PIVC-associated limb-splinting. Patients included in the case series were identified through screening of admissions in one ward of a tertiary paediatric hospital. Results: Five low-quality studies were included in the literature review. Three children were included in the case series. Each child acquired a PI subsequent to limb-splinting and taping adjacent to a PIVC. Hydration, nutritional state, and oxygenation did not appear to contribute to PI development in these cases. Conclusions: There is a gap in the evidence base pertaining to PIVC splinting and its involvement with PI formation in neonates, infants, and children. The existing literature provides low-quality evidence this problem exists; thus, further research is recommended.L20008214522018-06-08 <br />2018-06-12 <br />en
dc.language.isoenen
dc.relation.ispartofJAVA - Journal of the Association for Vascular Accessen
dc.titleNeonatal and Pediatric Pressure Injuries Secondary to Limb Splinting for Intravascular Access: Case Series and Literature Reviewen
dc.typeArticleen
dc.identifier.doi10.1016/j.java.2018.04.001en
dc.subject.keywordscase reporten
dc.subject.keywordscatheter removalen
dc.subject.keywordsclinical articleen
dc.subject.keywordsfemaleen
dc.subject.keywordshigh risk patienten
dc.subject.keywordshospital acquired pneumoniaen
dc.subject.keywordshumanen
dc.subject.keywordsinfanten
dc.subject.keywordsinfant feedingen
dc.subject.keywordslimb injuryen
dc.subject.keywordscefotaximeen
dc.subject.keywordspressureen
dc.subject.keywordsrisk factoren
dc.subject.keywordssplintingen
dc.subject.keywordsvascular accessen
dc.subject.keywordswound careen
dc.subject.keywordsintravascular catheterantibiotic agenten
dc.subject.keywordsmaleen
dc.subject.keywordsarticleen
dc.subject.keywordsblisteren
dc.subject.keywordsbronchiolitisen
dc.relation.urlhttps://www.embase.com/search/results?subaction=viewrecord&id=L2000821452&from=exporthttp://dx.doi.org/10.1016/j.java.2018.04.001 |en
dc.identifier.risid8en
dc.description.pages108-116en
item.cerifentitytypePublications-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Sites:Children's Health Queensland Publications
Show simple item record

Page view(s)

34
checked on Apr 17, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.