Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/3366
Full metadata record
DC FieldValueLanguage
dc.contributor.authorWalsh, H. P. J.en
dc.contributor.authorCarty, Christopheren
dc.contributor.authorDavico, G.en
dc.contributor.authorPizzolato, C.en
dc.contributor.authorLloyd, D. G.en
dc.contributor.authorObst, S. J.en
dc.date.accessioned2022-11-07T23:41:33Z-
dc.date.available2022-11-07T23:41:33Z-
dc.date.issued2020en
dc.identifier.citation72 , 2020, p. 141-149en
dc.identifier.otherRISen
dc.identifier.urihttp://dora.health.qld.gov.au/qldresearchjspui/handle/1/3366-
dc.description.abstractBackground: Cerebral palsy is a complex neuromuscular disorder that affects the sufferers in multiple different ways. Neuromusculoskeletal models are promising tools that can be used to plan patient-specific treatments for cerebral palsy. However, current neuromusculoskeletal models are typically scaled from generic adult templates that poorly represent paediatric populations. Furthermore, muscle activations are commonly computed via optimisation methods, which may not reproduce co-contraction observed in cerebral palsy. Alternatively, calibrated EMG-informed approaches within OpenSim can capture pathology-related muscle activation abnormalities, possibly enabling more feasible estimations of muscle and joint contact forces. Methods: Two identical twin brothers, aged 13, one with unilateral cerebral palsy and the other typically developing, were enrolled in the study. Four neuromusculoskeletal models with increasing subject-specificity were built in OpenSim and CEINMS combining literature findings, experimental motion capture, EMG and MR data for both participants. The physiological and biomechanical validity of each model was assessed by quantifying its ability to track experimental joint moments and muscle excitations. Findings: All developed models accurately tracked external joint moments; however EMG-informed models better tracked muscle excitations compared to neural solutions generated by static optimisation. Calibrating muscle-tendon unit parameters with EMG data allowed for more physiologically plausible joint contact forces estimates. Further scaling the maximal isometric force of muscles with MR-derived muscle volumes did not affect model predictions. Interpretation: Given their ability to identify atypical joint contact forces profiles and accurately reproduce experimental data, calibrated EMG-informed models should be preferred over generic models using optimisation methods in informing the management of cerebral palsy.L20043504202019-12-27 <br />2020-01-07 <br />en
dc.language.isoenen
dc.relation.ispartofClinical Biomechanicsen
dc.titleIncreasing level of neuromusculoskeletal model personalisation to investigate joint contact forces in cerebral palsy: A twin case studyen
dc.typeArticleen
dc.identifier.doi10.1016/j.clinbiomech.2019.12.011en
dc.subject.keywordsclinical articleen
dc.subject.keywordselectromyogramen
dc.subject.keywordsgaiten
dc.subject.keywordshumanen
dc.subject.keywordsimage processingen
dc.subject.keywordsjoint functionen
dc.subject.keywordsmaleen
dc.subject.keywordsmonozygotic twinsen
dc.subject.keywordsmotion analysis systemadolescenten
dc.subject.keywordsmuscle massen
dc.subject.keywordsneuromusculoskeletal modelen
dc.subject.keywordsnuclear magnetic resonance imagingen
dc.subject.keywordspriority journalen
dc.subject.keywordsmuscle excitationen
dc.subject.keywordsarticleen
dc.subject.keywordsbiological modelen
dc.subject.keywordsbiomechanicsen
dc.subject.keywordscase reporten
dc.subject.keywordscerebral palsyen
dc.relation.urlhttps://www.embase.com/search/results?subaction=viewrecord&id=L2004350420&from=exporthttp://dx.doi.org/10.1016/j.clinbiomech.2019.12.011 |en
dc.identifier.risid1613en
dc.description.pages141-149en
item.grantfulltextnone-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
Appears in Sites:Children's Health Queensland Publications
Show simple item record

Page view(s)

110
checked on Apr 22, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.