Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/3338
Title: Improving the central venous access devices maintenance process to reduce associated infections in paediatrics: Evaluation of a practical, multi-faceted quality-improvement initiative
Authors: Kleidon, T 
Edwards, R.
Fogarty, G.
Illing, A.
Ullman, Amanda 
Tomlinson, J.
Issue Date: 2015
Source: 20, (2), 2015, p. 46-53
Pages: 46-53
Journal: Healthcare Infection
Abstract: Introduction Central venous access devices (CVADs) provide essential and reliable vascular access, but infection is a common and serious complication with paediatric patients. CVAD bundles have been demonstrated to effectively reduce central line-associated bloodstream infections (CLABSI), but primarily during CVAD insertion. Another emerging strategy to encourage best practice is the use of a dedicated CVAD trolley for maintenance. Methods A quality-improvement initiative was undertaken to improve CVAD maintenance and to evaluate the effectiveness of the chosen interventions at the Royal Children's Hospital, Brisbane. Nursing staff from four wards within the hospital elected to participate and the wards were allocated to receive either Intervention A (CVAD maintenance bundle only) or Intervention B (CVAD maintenance bundle and dedicated CVAD trolley). Effectiveness of the interventions was evaluated by: (i) rate of CLABSI per 1000 catheter-days; and (ii) audits of clinician compliance with evidence-based CVAD maintenance strategies. Results During the initiative, the hospital-wide CLABSI rate decreased from 9.07 to 1.05 episodes per 1000 catheter-days (P≤0.01). The rate of CLABSI in Intervention A wards reduced from 7.6 to 2.2 episodes per 1000 catheter-days (P<0.001) and in Intervention B wards reduced from 8.0 to 0.5 episodes per 1000 catheter-days (P<0.001). Hospital-wide audits of clinician compliance increased from 11.9% to 35% (P≤0.001) in the Intervention A wards and to 83% (P<0.001) in the Intervention B wards. Conclusion Implementation of CVAD maintenance bundles and a dedicated CVAD trolley successfully reduced CLABSI and improved audited compliance to evidence-based practices within our tertiary paediatric hospital.L6046244692015-06-05
2015-06-18
DOI: 10.1071/HI14038
Resources: https://www.embase.com/search/results?subaction=viewrecord&id=L604624469&from=exporthttp://dx.doi.org/10.1071/HI14038 |
Keywords: human;clinical audit;outcome assessment;pediatrics;total quality management;catheter infection;central venous catheterarticle;vascular access;child;clinical practice;health care quality
Type: Article
Appears in Sites:Children's Health Queensland Publications

Show full item record

Page view(s)

74
checked on Mar 18, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.