Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/2764
Title: Effect of sex and fatigue on single leg squat kinematics in healthy young adults Rehabilitation, physical therapy and occupational health
Authors: Weeks, B. K.
Carty, Christopher 
Horan, S. A.
Issue Date: 2015
Source: 16, (1), 2015
Journal: BMC Musculoskeletal Disorders
Abstract: Background: The single-leg squat (SLS) test is widely used in screening for musculoskeletal injury risk. Little is known, however, of lower limb, pelvis, and trunk kinematics of SLS performance or the effect of sex and fatigue. Our aim was to determine sex differences and the influence of fatigue on SLS kinematics in healthy young adults. Methods: We recruited 60 healthy men and women between the ages of 20 and 40 years. Three-dimensional kinematic data was collected for SLSs with a ten-camera VICON motion analysis system (Oxford Metrics, UK) before and after a lower limb fatiguing exercise regime. One-way ANCOVA was used to make sex comparisons of kinematic parameters and repeated measures ANOVA was used to determine the effect of fatigue and the interaction with sex. Results: 30 men (25.6∈±∈4.8 years) and 30 women (25.1∈±∈3.8 years) volunteered to participate. Peak pelvic rotation (3.9∈±∈4.1 vs. 7.7∈±∈6.2 deg, P∈=∈0.03), peak hip internal rotation (-1.8∈±∈5.7 vs. 3.0∈±∈7.3 deg, P∈=∈0.02), hip adduction range (11.7∈±∈4.8 vs. 18.3∈±∈6.7 deg, P∈=∈0.004), and hip rotation range (10.7∈±∈3.9 vs. 13.0∈±∈4.2 deg, P∈=∈0.04) were smaller for men than for women. Likewise, distance of mediolateral knee motion (180∈±∈51 vs. 227∈±∈50 mm, P∈=∈0.001) was shorter for men than for women. The kinematic response to fatigue was an increase in trunk flexion, lateral flexion and rotation, an increase in pelvic tilt, obliquity and rotation, and an increase in hip flexion and adduction range (P ≤0.05). Conclusions: Sex differences in SLS kinematics appear to apply only at the hip, knee, and pelvis and not at the trunk. Fatiguing exercise, however, produces changes at the trunk and pelvis with little effect on the knee.L6061848352015-10-08
2015-10-13
DOI: 10.1186/s12891-015-0739-3
Resources: https://www.embase.com/search/results?subaction=viewrecord&id=L606184835&from=exporthttp://dx.doi.org/10.1186/s12891-015-0739-3 |
Keywords: human;human experiment;joint mobility;kinematics;knee function;leg exercise;male;motion analysis system;musculoskeletal system examination;normal human;pelvis;pretest posttest design;range of motion;sex difference;single leg squat;task performance;three-dimensional imaging;trunk;MX13 camera;VICON motion analysis system;female;fatigue;controlled study;adductionadult;article;hip
Type: Article
Appears in Sites:Children's Health Queensland Publications

Show full item record

Page view(s)

90
checked on Mar 20, 2025

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.