Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/2680
Title: Dressed for success: A pilot study of central venous access device securement and dressing effectiveness in the PICU
Authors: Williams, T.
Rickard, C.
Mihala, G.
Mattke, A.
Pearson, K.
Ullman, Amanda 
Long, D.
Issue Date: 2018
Source: 19, (6), 2018, p. 192-193
Pages: 192-193
Journal: Pediatric Critical Care Medicine
Abstract: Aims & Objectives: Central venous access devices (CVADs) are used to provide reliable vascular access during critical illness, however 25% fail before completion of treatment. Failure is frequently attributed to inadequate securement and dressing. This study aimed to establish the feasibility of an efficacy randomised control trial (RCT) of current and new technologies to secure paediatric CVADs. Methods A single centre, parallel, superiority, pilot RCT of 179 paediatric patients with non-tunnelled CVADs admitted to the PICU at Lady Cilento Children's Hospital, Australia. Participants were randomised to receive CVAD dressing and securement: 1. Standard care: Bordered polyurethane dressing, with sutures and chlorhexidine gluconate (CHG) disc; 2. Tissue adhesive (Histoacryl®): with standard care; 3. Engineered securement dressing: (SorbaView SHIELD®): with sutures and CHG disc. Outcomes: Primary: Feasibility (including effect estimates); Secondary: CVAD failure, complication; family/ staff acceptability, skin damage and dressing performance Results Feasibility criteria were achieved as suitable recruitment rates, low rates of attrition and good protocol adherence were achieved. Family members and staff reported comparable acceptability for intervention arms, however tissue adhesive was most difficult to apply. There were low rates of failure within all the study arms with 2% (1/56) in engineered dressing, 6% (3/54) in standard care, and 10% (6/59) in tissue adhesive. Non-routine dressing changes were lower in the engineered dressing (13%) and tissue adhesive (10%) groups, in comparison to standard care (28%). Conclusions It is feasible to conduct an efficacy RCT of the studied interventions. Further research is required to definitively identify clinical, cost-effective securement methods to prevent CVAD failure.L6238158602018-09-13
Resources: https://www.embase.com/search/results?subaction=viewrecord&id=L623815860&from=export
Keywords: suture;wound dressing;skin defect;chlorhexidine gluconatepolyurethan;tissue adhesive;Australia;child;complication;conference abstract;controlled study;device failure;feasibility study;female;human;major clinical study;pediatric intensive care unit;pediatric patient;pilot study;protocol compliance;randomized controlled trial;staff
Type: Article
Appears in Sites:Children's Health Queensland Publications

Show full item record

Page view(s)

82
checked on Mar 18, 2025

Google ScholarTM

Check


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.