Please use this identifier to cite or link to this item: https://dora.health.qld.gov.au/qldresearchjspui/handle/1/1603
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGhandourh, Wsamen_US
dc.contributor.authorDowling, Jasonen_US
dc.contributor.authorChlap, Phillipen_US
dc.contributor.authorOar, Andrewen_US
dc.contributor.authorJacob, Susannahen_US
dc.contributor.authorBatumalai, Vikneswaryen_US
dc.contributor.authorHolloway, Loisen_US
dc.date.accessioned2021-09-29T04:20:06Z-
dc.date.available2021-09-29T04:20:06Z-
dc.date.issued2020-10-
dc.identifier.citationGhandourh W, Dowling J, Chlap P, Oar A, Jacob S, Batumalai V, Holloway L. Assessing tumor centrality in lung stereotactic ablative body radiotherapy (SABR): the effects of variations in bronchial tree delineation and potential for automated methods. Med Dosim. 2021 Spring;46(1):94-101. doi: 10.1016/j.meddos.2020.09.004en_US
dc.identifier.urihttp://dora.health.qld.gov.au/qldresearchjspui/handle/1/1603-
dc.description.abstractAccurate delineation of the proximal bronchial tree (PBT) is crucial for appropriate assessment of lung tumor centrality and choice of Stereotactic Ablative Body Radiotherapy (SABR) dose prescription. Here, we investigate variabilities in manual PBT delineation and their potential to influence assessing lesion centrality. A fully automatic, intensity-based tool for PBT contouring and measuring distance to the target is also described. This retrospective analysis included a total of 61 patients treated with lung SABR. A subset of 41 patients was used as a training dataset, containing clinical PBT contour and additional subsequently generated manual contours. The tool was optimized and compared against manual contours in terms of volume, distance to the target and various overlap/similarity metrics. The remaining 20 patients were used as a validation dataset to investigate the dosimetric effects of variations between manual and automatic PBT contours. Considerable interobserver variability was observed, particularly in identifying the superior and inferior borders of the PBT. Automatic PBT contours were comparable to manual contours with average Dice of 0.63 to 0.79 and mean distance to agreement of 1.78 to 3.34 mm. No significant differences in dosimetric parameters were found between automatically and manually generated contours. A moderate negative correlation was found between PBT maximum dose and distance to the lesion (p < 0.05). Variability in manual PBT delineation may result in inconsistent assessment of tumor centrality. Automatic contouring can help standardize clinical practice, support investigations into the link between SABR outcomes and lesion proximity to central airways and the development of predictive toxicity models that incorporate precise measurements of tumor location in relation to high-risk organs.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofMedical dosimetry : official journal of the American Association of Medical Dosimetristsen_US
dc.subjectAutomatic contouringen_US
dc.subjectNSCLCen_US
dc.subjectStereotactic radiotherapyen_US
dc.subjectCentral tumorsen_US
dc.subjectContour variationsen_US
dc.titleAssessing tumor centrality in lung stereotactic ablative body radiotherapy (SABR): the effects of variations in bronchial tree delineation and potential for automated methodsen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.meddos.2020.09.004-
item.openairetypeArticle-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Sites:Gold Coast Health Publications
Show simple item record

Page view(s)

92
checked on Nov 23, 2024

Google ScholarTM

Check

Altmetric


Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.