Please use this identifier to cite or link to this item:
https://dora.health.qld.gov.au/qldresearchjspui/handle/1/12322| Title: | Use of central venous access devices outside of the pediatric intensive care units | Authors: | Burek, A. G.;Bumgardner, C.;Liljestrom, T.;Porada, K.;Pan, A. Y.;Liegl, M.;Coon, E. R.;Flynn, K. E.;Ullman, A. J. ;Brousseau, D. C. | Issue Date: | 2025 | Source: | Pediatr Res, 2025 (97) 2 p.664-670 | Pages: | 664-670 | Journal Title: | Pediatr Res | Abstract: | BACKGROUND: Central venous access devices (CVAD) are associated with central line associated bloodstream infection (CLABSI) and venous thromboembolism (VTE). We identified trends in non-intensive care unit (ICU) CVAD utilization, described complication rates, and compared resources between low and high CVAD sites. METHODS: We combined data from the Pediatric Health Information System (PHIS) database and surveys from included hospitals. We analyzed 10-year trends in CVAD encounters for non-ICU children between 01/2012-12/2021 and described variation and complication rates between 01/2017-12/2021. Using Fisher's exact test, we compared resources between low and high CVAD users. RESULTS: CVAD use decreased from 6.3% to 3.8% of hospitalizations over 10 years. From 2017-2021, 67,830 encounters with CVAD were identified. Median age was 7 (IQR 2-13) years; 46% were female. Significant variation in CVAD utilization exists (range 1.4-16.9%). Rates of CLABSI and VTE were 4.0% and 3.4%, respectively. Survey responses from 33/41 (80%) hospitals showed 91% had vascular access teams, 30% used vascular access selection guides, and 70% used midline/long peripheral catheters. Low CVAD users were more likely to have a team guiding device selection (100% vs 43%, p = 0.026). CONCLUSIONS: CVAD utilization decreased over time. Significant variation in CVAD use remains and may be associated with hospital resources. IMPACT: Central venous access device (CVAD) use outside of the ICU is trending down; however, significant variation exists between institutions. Children with CVADs hospitalized on the acute care units had a CLABSI rate of 4% and VTE rate of 3.4%. 91% of surveyed institutions have a vascular access team; however, the services provided vary between institutions. Even though 70% of the surveyed institutions have the ability to place midline/long peripheral catheters, the majority use these catheters less than a few times per month. Institutions with low CVAD use are more likely to have a vascular access team that guides device selection. | DOI: | 10.1038/s41390-024-03337-7 |
| Appears in Sites: | Children's Health Queensland Publications Queensland Health Publications |
Show full item record
Items in DORA are protected by copyright, with all rights reserved, unless otherwise indicated.